Cookie preferences
This website uses cookies, which are necessary for the technical operation of the website and are always set. Other cookies, which increase the comfort when using this website, are used for direct advertising or to facilitate interaction with other websites and social networks, are only set with your consent.
Configuration
Technically required
These cookies are necessary for the basic functions of the shop.
"Allow all cookies" cookie
"Decline all cookies" cookie
CSRF token
Cookie preferences
Currency change
Customer-specific caching
FACT-Finder tracking
Individual prices
Selected shop
Session
Comfort functions
These cookies are used to make the shopping experience even more appealing, for example for the recognition of the visitor.
Note
Show the facebook fanpage in the right blod sidebar
Statistics & Tracking
Affiliate program
Conversion and usertracking via Google Tag Manager
Track device being used
Close filters
Filter by:
No results were found for the filter!
Item number: BOT-10025
For researchers wishing to investigate the suitability of our various chromogenic beta-glucuronidase substrates, we offer this sampler kit, which contains 5 mg each of the following three different substrates: X-GlcU, CHA, Red-beta-D-GlcU, CHA, and Rose-beta-D-GlcU, CHA.
325.00€
*
Item number: BOT-10123
For researchers wishing to screen for the appropriate coelenterazine derivatives to use, we offer this kit with 25 ug each of nine coelenterazine analogs: coelenterazine, coelenterazine cp, coelenterazine f, coelenterazine fcp, coelenterazine h, coelenterazine hcp, coelenterazine i, coelenterazine ip, and...
342.00€
*
Item number: BOT-22026
Mini syringe filters are convenient for sterile filtration of small volumes (1 mL or less) with only 10 uL retention volume. Millex(R)-GV 0.22 um hydrophilic PVDF membrane in a 4 mm filter. Kit includes sterile filters, 1 cc syringes, and screw cap vials, 5 each.
103.00€
*
Item number: BOT-23006
Flow Cytometry Fixation/Permeabilization Kit contains optimally formulated buffers for fixation and permeabilization of suspension cells for immunofluorescence staining of intracellular antigens for analysis by flow cytometry. Note: the fixation buffer in this kit is prepared from methanol-stabilized formaldehyde....
48.00€
*
Item number: BOT-23013
The TrueBlack(R) WB blocking buffer is a buffer system designed to achieve optimal specificity and sensitivity by blocking background from the non-specific interaction between the fluorophore-labeled antibodies and the membrane with cell lysates. For blocking and antibody dilution for 10 membranes.
Keywords: | Western Blot |
From 126.00€
*
Item number: BOT-30001
The loss of mitochondrial membrane potential is a hallmark for apoptosis. It is an early event preceding phosphatidylserine externalization and coinciding with caspase activation. JC-1 Mitochondrial Membrane Potential Detection Kit is used to measure mitochondrial membrane potential changes in cells. In...
From 123.00€
*
Item number: BOT-30015
DAB (3,3'-diaminobenzidine) reacts with HRP in the presence of peroxide to yield an insoluble brown-colored product at locations where peroxidase-conjugated antibodies are bound to samples. The brown precipitate is insoluble in alcohol and other organic solvents, making it an excellent substrate for...
158.00€
*
Item number: BOT-30024
CellBrite(TM) Cytoplasmic Membrane Labeling Kits are designed to label cell cytoplasmic membranes with fluorescent dyes, available in blue, green, orange, and red. The labeling is stable and nontoxic, suitable for long-term tracking of cells. By combining multiple CellBrite(TM) Cytoplasmic Membrane Stains, one can...
324.00€
*
Item number: BOT-30037
The DiO/DPA system detects cytoplasmic membrane potential changes using the principle of fluorescence resonance energy transfer (FRET), where DiO is a "stationary" FRET donor while DPA acts as a potentiometric FRET acceptor. The DiO/DPA system has been reported to produce a fluorescence signal change of >56% in...
365.00€
*
Item number: BOT-30050
ViaFluor(R) SE Cell Proliferation Kits use amine-reactive dyes to covalently label cells throughout the cell cytoplasm and intracellular compartments. Cell proliferation dyes are commonly used to monitor cell division by flow cytometry. The dyes also can be used to stably label cells to image cell morphology, or to...
193.00€
*
Item number: BOT-30068
ViaFluor(R) SE Cell Proliferation Dyes are fluorescent tracers for tracking cell division by flow cytometry, ViaFluor(R) 405 SE Cell Proliferation Dye is an improved replacement for the classical proliferation dye CFSE. It can be detected in the Pacific Blue channel with violet laser excitation.
Keywords: | Proliferation |
From 112.00€
*
Item number: BOT-30071
AccuOrange(TM) Protein Quantitation Kit is a highly sensitive fluorescence-based assay for quantitating purified protein samples in 96-well format. The detection range of the assay is 0.1-15 ug/mL protein. AccuOrange(TM) is much more sensitive than traditional protein quantitation assays such as BCA, Bradford and...
From 81.00€
*