CytoTell(TM) Red

CytoTell(TM) Red
Item number Size Datasheet Manual SDS Delivery time Quantity Price
ABD-22255 500 tests -

3 - 8 business days*

139.00€
ABD-22256 1000 tests -

3 - 8 business days*

208.00€
 
Ex: 628 nm. Em: 643 nm. Soluble in: DMSO. Flow cytometry combined with fluorescence staining is a... more
Product information "CytoTell(TM) Red"
Ex: 628 nm. Em: 643 nm. Soluble in: DMSO. Flow cytometry combined with fluorescence staining is a powerful tool to analyze heterogeneous cell populations. Among all the existing fluorescent dyes CFSE is the preferred cell proliferation indicator that is widely used for live cell analysis. However, it is impossible to use CFSE and its fluorescein analogs for GFP-transfected cells or for the applications where a FITC-labeled antibody is used since CFSE and its fluorescein analogs have the excitation and emission spectra almost identical to GFP or FITC. CytoTellT dyes are well excited at major laser lines such as 405 nm, 488 nm or 633 nm with multicolor emissions. CytoTellT dyes have minimal cytotoxicity, and are used for the multicolor applications with either GFP cell lines or FITC-labeled antibodies since they have either excitation or emission spectra distinct from fluorescein. CytoTellT Red is a red fluorescent dye that stains cells evenly. As cells divide, the dye is distributed equally between daughter cells that can be measured as successive halving of the fluorescence intensity of the dye. Up to 8 generations may be visualized. CytoTellT Red can also be used for long term tracking of labeled cells. Analysis using two-parameter plots may provide better resolution of each generation, especially between undivided cells and the first generation. Cells labeled with Cell CytoTellT Red may be fixed and permeabilized for analysis of intracellular targets using standard formaldehyde-containing fixatives and saponin-based permeabilization buffers. CytoTellT Red has a peak excitation of 630 nm and can be excited by the red (633 nm) laser line. It has a peak emission of 660 nm and can be detected with a 660/20 band pass filter (equivalent to APC, Alexa Fluor® 647, or Cy5®), making it compatible with applications that utilize GFP or FITC antibodies for multicolor cell analysis.
Supplier: AAT Bioquest
Supplier-Nr: 22255

Properties

Application: Cell-based assays, fluorescent cell labeling, FC
MW: ~600 D

Database Information

Handling & Safety

Storage: -20°C
Shipping: +20°C (International: +20°C)
Caution
Our products are for laboratory research use only: Not for administration to humans!
You will get a certificate here
or to request a certificate of analysis.
Read, write and discuss reviews... more
Customer review for "CytoTell(TM) Red"
Write a review
or to review a product.
Viewed