Cookie preferences
This website uses cookies, which are necessary for the technical operation of the website and are always set. Other cookies, which increase the comfort when using this website, are used for direct advertising or to facilitate interaction with other websites and social networks, are only set with your consent.
Configuration
Technically required
These cookies are necessary for the basic functions of the shop.
"Allow all cookies" cookie
"Decline all cookies" cookie
CSRF token
Cookie preferences
Currency change
Customer-specific caching
FACT-Finder tracking
Individual prices
Selected shop
Session
Comfort functions
These cookies are used to make the shopping experience even more appealing, for example for the recognition of the visitor.
Note
Show the facebook fanpage in the right blod sidebar
Statistics & Tracking
Affiliate program
Conversion and usertracking via Google Tag Manager
Track device being used
If you intend to use this Cytion cell line solely for internal research at a single research site, please complete and sign the Material Transfer Agreement (MTA) and submit it along with your order. For any commercial applications – including but not limited to fee-for-service work, quality control testing, product release, diagnostic use, or regulatory studies – please complete the Intended Use Form so we can prepare a suitable agreement tailored to your project.
| Item number | Size | Datasheet | Manual | SDS | Delivery time | Quantity | Price |
|---|---|---|---|---|---|---|---|
| CYT-300133 | 1 each | - |
5-10 business days* |
430.00€
|
If you have any questions, please use our Contact Form.
You can also order by e-mail: info@biomol.com
Larger quantity required? Request bulk
You can also order by e-mail: info@biomol.com
Larger quantity required? Request bulk
Categories: Leukemia cell lines Description: The BV-173 cell line originates from the peripheral... more
Product information "BV-173 Cells"
Categories: Leukemia cell lines Description: The BV-173 cell line originates from the peripheral blood of a patient diagnosed with Philadelphia chromosome-positive (Ph+) chronic myeloid leukemia (CML), established in 1980. This cell line is particularly noted for its Ph+ status, which is indicative of a specific chromosomal abnormality involving the translocation between chromosome 9 and chromosome 22. This translocation, often referred to as the Philadelphia chromosome, results in the BCR-ABL fusion gene, a critical molecular hallmark that drives the pathogenesis of CML by promoting leukemic cell proliferation and survival. BV-173 cells are used extensively in hematological research as a model to study the cellular and molecular mechanisms of CML, especially in the context of drug resistance and the cellular response to tyrosine kinase inhibitors (TKIs), which target the BCR-ABL fusion protein. The cell line has been instrumental in preclinical studies for evaluating new therapeutic strategies and understanding the biology of CML. BV-173 exhibits characteristics typical of myeloid lineage cells and is often used to study signal transduction pathways that are deregulated in CML due to the BCR-ABL oncogene. Organism: Human Tissue: Blood Disease: Chronic myeloid leukemia Age: 45 years Gender: Male Ethnicity: Caucasian Cell Type: Undifferentiated blast cells Growth Properties: Suspension Citation: BV-173 (Cytion catalog number 300133) Biosafety Level: 1 Ncbi_ Taxid: 9606.0 Cellosaurus Accession: CVCL_0181 Reverse Transcriptase: Negative (ELISA) Ploidy Status: t(9, 22) Modal Number: 2n=46 Mutational Profile: b2a2 BCR-ABL Culture Medium: RPMI 1640, w: 2.0 mM stable Glutamine, w: 2.0 g/L NaHCO3 (Cytion article number 820700a) Supplements: Supplement the medium with 10% heat-inactivated FBS Doubling Time: 35 hours Subculturing: Maintain cultures by periodically adding or replacing the medium. Initiate cultures with a density of 5 x 105 cells/ml and keep the cell concentration within the range of 3 x 105 to 1 x 106 cells/ml for optimal growth. Seeding Density: 1 x 105 cells/ml Fluid Renewal: 2 to 3 times per week Post Thaw Recovery: Allow the cells to recover from the freezing process for at least 48 hours. Freeze Medium: As a cryopreservation medium, use complete growth medium (including FBS) + 10% DMSO for adequate post-thaw viability, or CM-1 (Cytion catalog number 800100), which includes optimized osmoprotectants and metabolic stabilizers to enhance recovery and reduce cryo-induced stress. Thawing And Culturing Cells: Confirm that the vial remains deeply frozen upon delivery, as cells are shipped on dry ice to maintain optimal temperatures during transit. Upon receipt, either store the cryovial immediately at temperatures below -150°C to ensure the preservation of cellular integrity, or proceed to step 3 if immediate culturing is required. For immediate culturing, swiftly thaw the vial by immersing it in a 37°C water bath with clean water and an antimicrobial agent, agitating gently for 40-60 seconds until a small ice clump remains. Perform all subsequent steps under sterile conditions in a flow hood, disinfecting the cryovial with 70% ethanol before opening. Carefully open the disinfected vial and transfer the cell suspension into a 15 ml centrifuge tube containing 8 ml of room-temperature culture medium, mixing gently. Centrifuge the mixture at 300 x g for 3 minutes to separate the cells and carefully discard the supernatant containing residual freezing medium. Gently resuspend the cell pellet in 10 ml of fresh culture medium. For adherent cells, divide the suspension between two T25 culture flasks, for suspension cultures, transfer all the medium into one T25 flask to promote effective cell interaction and growth. Adhere to established subculture protocols for continued growth and maintenance of the cell line, ensuring reliable experimental outcomes. Sterility: Mycoplasma contamination is excluded using both PCR-based assays and luminescence-based mycoplasma detection methods. To ensure there is no bacterial, fungal, or yeast contamination, cell cultures are subjected to daily visual inspections. Safety Precautions: When planning to store a cryovial in liquid nitrogen for future thawing, it is mandatory to adhere to stringent safety measures. Appropriate protective gloves and clothing are essential, and the use of a face mask or safety goggles is required during the transfer of frozen samples to or from the liquid nitrogen tank. This is to mitigate the risk of injury from potential cryovial explosions upon removal, which can result in the projection of sharp fragments. Warranty: We stand by the promise of delivering products with high cell viability and robust culture performance. To achieve the best results, please make sure you follow the storage and culture instructions detailed in the product information sheet closely. Your adherence to these guidelines is key to success. Subject To Material Transfer Agreements: If you intend to use Cytion cell lines solely for internal research at a single research site, please complete and sign our Material Transfer Agreement (MTA) and submit it along with your order.For any commercial applications - including but not limited to fee-for-service work, quality control testing, product release, diagnostic use, or regulatory studies - please complete the Intended Use Form so we can prepare a suitable agreement tailored to your project.Please note: The MTA applies only to certain cell lines. If this notice and the MTA document appear on a product page, the agreement is applicable. For cell lines not covered by the MTA, no reference to the agreement will be shown. The MTA is not valid for customers in the Americas, China, or Taiwan. Please contact our U.S. entity to receive the appropriate agreement. Required Product 1: 820700a Required Product 3: 860015.0 Required Product 4: 830100.0
| Supplier: | Cytion |
| Supplier-Nr: | 300133 |
Properties
| Host: | Human |
| Species reactivity: | human |
Database Information
Handling & Safety
| Storage: | Liquid nitrogen |
| Shipping: | -80°C (International: -80°C) |
Caution
Our products are for laboratory research use only: Not for administration to humans!
Our products are for laboratory research use only: Not for administration to humans!
You will get a certificate here
Viewed