Cell Meter(TM) APC-Annexin V Binding Apoptosis Assay Kit *Optimized for Flow Cytometry*

Cell Meter(TM) APC-Annexin V Binding Apoptosis Assay Kit *Optimized for Flow Cytometry*
Artikelnummer Größe Datenblatt Manual SDB Lieferzeit Menge Preis
ABD-22837 100 tests -

3 - 8 Werktage*

285,00 €
 
Ex: 651 nm. Em: 662 nm. Annexin V may be conjugated to fluorochromes including APC. This format... mehr
Produktinformationen "Cell Meter(TM) APC-Annexin V Binding Apoptosis Assay Kit *Optimized for Flow Cytometry*"
Ex: 651 nm. Em: 662 nm. Annexin V may be conjugated to fluorochromes including APC. This format retains its high affinity for phosphatidylserine (PS) and thus serves as a sensitive probe for flow cytometric analysis of cells that are undergoing apoptosis. Since externalization of PS occurs in the earlier stages of apoptosis, APC Annexin V staining can identify apoptosis at an earlier stage than assays based on nuclear changes such as DNA fragmentation. APC Annexin V staining precedes the loss of membrane integrity which accompanies the latest stages of cell death resulting from either apoptotic or necrotic processes. Therefore, staining with APC Annexin V is typically used in conjunction with a vital dye such as propidium iodide (PI) or 7-Amino-Actinomycin (7-AAD) to allow the investigator to identify early apoptotic cells (7-AAD negative, APC Annexin V positive). Viable cells with intact membranes exclude 7-AAD, whereas the membranes of dead and damaged cells are permeable to 7-AAD. For example, cells that are considered viable are both APC Annexin V and 7-AAD negative while cells that are in early apoptosis are APC Annexin V positive and 7-AAD negative, while cells that are in late apoptosis or already dead are both APC Annexin V and 7-AAD positive. This assay does not distinguish between cells that have undergone apoptotic death versus those that have died as a result of a necrotic pathway because in either case, the dead cells will stain with both APC Annexin V and 7-AAD. However, when apoptosis is measured over time, cells can be often tracked from APC Annexin V and 7-AAD negative (viable, or no measurable apoptosis), to APC Annexin V positive and 7-AAD negative (early apoptosis, membrane integrity is present) and finally to APC Annexin V and 7-AAD positive (end stage apoptosis and death). The movement of cells through these three stages suggests apoptosis. In contrast, a single observation indicating that cells are both APC Annexin V and 7-AAD positive, in of itself, reveals less information about the process by which the cells underwent their demise.
Hersteller: AAT Bioquest
Hersteller-Nr: 22837

Eigenschaften

Anwendung: FC
Format: Homog.

Datenbank Information

Handhabung & Sicherheit

Lagerung: +4°C (protect from light)
Versand: +4°C (International: +4°C)
Achtung
Nur für Forschungszwecke und Laboruntersuchungen: Nicht für die Anwendung im oder am Menschen!