SPM E-series MaxSpec(R) LC-MS Mixture

SPM E-series MaxSpec(R) LC-MS Mixture
Artikelnummer Größe Datenblatt Manual SDB Lieferzeit Menge Preis
Cay19417-1 1 each -

6 - 10 Werktage*

243,00 €
 
This mixture contains an E-series resolvin (specialized pro-resolving mediator, SPM) and its... mehr
Produktinformationen "SPM E-series MaxSpec(R) LC-MS Mixture"
This mixture contains an E-series resolvin (specialized pro-resolving mediator, SPM) and its precursors, eicosapentaenoic acid (EPA, Cay-90110) and (±)18-HEPE (Cay-32840). The mixture is supplied in an amber ampule in which the headspace has been purged with argon to prevent lipid oxidation. This product has been designed for direct use in LC-MS applications. The solution may be serially diluted for preparation of calibrators and QC standards and/or used directly as a system suitability standard or tuning standard. After opening, we recommend that the mixture be transferred immediately to a 1 ml glass screw cap vial, to prevent solvent evaporation, and stored at -20°C. The mixture should be discarded after multiple freeze/thaw cycles.The fatty acids in this mixture represent the metabolic cascade of the E-series resolvins. Resolvin E1 (Cay-10007848) has been postulated to be an anti-inflammatory metabolite of EPA by way of an 18-HEPE intermediate. It has been identified in mouse inflammatory exudates and in human plasma when subjects are treated with both aspirin (Cay-70260) and supplemental EPA. Resolvin E1 has been shown to promote inflammatory resolution in numerous disease models, including experimental colitis, asthma, atherosclerosis, type 2 diabetes, and HSV-1-induced stromal keratitis.Synonyms: Specialized Pro-Resolving Mediator E-series LC-MS Mixture. Formulation: (Request formulation change), A solution in ethanol (100 ng/ml of each compound).
Schlagworte: Specialized Pro-Resolving Mediator E-series LC-MS Mixture
Hersteller: Cayman Chemical
Hersteller-Nr: 19417

Eigenschaften

Anwendung: LC-MS, calibrator / standard preparation
Format: Solution

Datenbank Information

Handhabung & Sicherheit

Lagerung: -80°C
Versand: -80°C (International: -80°C)
Signalwort: Danger
GHS-Piktogramme:
H-Sätze: H225, H319
P-Sätze: P210, P233, P240, P241, P242, P243, P264, P280, P303+361+353, P305+351+338, P337+313, P370+378, P403+235, P501
Achtung
Nur für Forschungszwecke und Laboruntersuchungen: Nicht für die Anwendung im oder am Menschen!
Hier kriegen Sie ein Zertifikat
oder , um Analysenzertifikate anzufordern.
Bewertungen lesen, schreiben und diskutieren... mehr
Kundenbewertungen für "SPM E-series MaxSpec(R) LC-MS Mixture"
Bewertung schreiben
oder , um eine Produktbewertung abzugeben.
Zuletzt angesehen