Sample Preparation Kits

2 from 14 pages
No results were found for the filter!
NEW
Strep-Tactin(R) coated microplate
Strep-Tactin(R) coated microplate

Item number: IBA-2-1501-001

Ready-to-use Strep-Tactin(R)-coated microplate (12 x 8-well strips) for ligand binding assays, immunoassays, enzyme assays, or diagnostic assays under high throughput conditions. Due to the high specificity and affinity (µM-nM) of the streptavidin variant Strep-Tactin(R), Strep-tag(R)II or Twin-Strep-tag(R) fusion...
Application: Ready-to-use microplate for assay applications
66.00€ *
Review
NEW
Strep-Tactin(R) MacroPrep(R) resin
Strep-Tactin(R) MacroPrep(R) resin

Item number: IBA-2-1505-010

Strep-Tactin(R) MacroPrep(R) consists of polymethacrylate, a synthetic material coupled with the streptavidin variant Strep-Tactin(R) and is applicable for purification of Strep-tag(R)II or Twin-Strep-tag(R) fusion proteins. In contrast to agarose resins, plant cell components such as chlorophyll are not...
Application: Strep-tag(R)II / Twin-Strep-tag(R) fusion proteins purification
487.00€ *
Review
NEW
MagStrep "type3" Strep-Tactin beads
MagStrep "type3" Strep-Tactin beads

Item number: IBA-2-1613-002

MagStrep "type3" Strep-Tactin(R) beads are magnetic beads with an agarose surface coated with the streptavidin variant Strep-Tactin(R) and intended for purification of biotinylated proteins. Originally, Strep-Tactin(R) was developed for binding and purification of Strep-tag(R)II and Twin-Strep-tag(R) proteins. The...
Application: Magnetic beads (5% suspension) to purify biotinylated proteins
283.00€ *
Review
NEW
Strep-Tactin(R)XT 4Flow(R) resin
Strep-Tactin(R)XT 4Flow(R) resin

Item number: IBA-2-5010-002

Strep-Tactin(R)XT 4Flow(R) is a 4% agarose coupled with the streptavidin variant Strep-Tactin(R)XT and applicable for purification of Strep-tag(R)II or Twin-Strep-tag(R) fusion proteins. Due to the broad pH compatibility, excellent pressure stability, outstanding target purity (> 95%), and highest binding affinity,...
Application: Strep-tag(R)II / Twin-Strep-tag(R) fusion proteins purification
From 116.00€ *
Review
NEW
Strep-Tactin(R)XT 4Flow(R) column
Strep-Tactin(R)XT 4Flow(R) column

Item number: IBA-2-5011-005

Strep-Tactin(R)XT 4Flow(R) columns contain a 4% agarose coupled with the streptavidin variant Strep-Tactin(R)XT and are applicable for purification of Strep-tag(R)II or Twin-Strep-tag(R) fusion proteins via gravity flow. Due to the broad pH compatibility, excellent pressure stability, outstanding target purity (>...
Application: Gravity flow column to purify Strep-tag(R)II or Twin-Strep-tag(R) fusion proteins
199.00€ *
Review
NEW
Strep-Tactin(R)XT 4Flow(R) column
Strep-Tactin(R)XT 4Flow(R) column

Item number: IBA-2-5012-001

Strep-Tactin(R)XT 4Flow(R) columns contain a 4% agarose coupled with the streptavidin variant Strep-Tactin(R)XT and are applicable for purification of Strep-tag(R)II or Twin-Strep-tag(R) fusion proteins via gravity flow. Due to the broad pH compatibility, excellent pressure stability, outstanding target purity (>...
Application: Gravity flow column to purify Strep-tag(R)II or Twin-Strep-tag(R) fusion proteins
85.00€ *
Review
NEW
Strep-Tactin(R)XT 4Flow(R) column
Strep-Tactin(R)XT 4Flow(R) column

Item number: IBA-2-5013-001

Strep-Tactin(R)XT 4Flow(R) columns contain a 4% agarose coupled with the streptavidin variant Strep-Tactin(R)XT and are applicable for purification of Strep-tag(R)II or Twin-Strep-tag(R) fusion proteins via gravity flow. Due to the broad pH compatibility, excellent pressure stability, outstanding target purity (>...
Application: Gravity flow column to purify Strep-tag(R)II or Twin-Strep-tag(R) fusion proteins
256.00€ *
Review
NEW
Strep-Tactin(R)XT 4Flow(R) column
Strep-Tactin(R)XT 4Flow(R) column

Item number: IBA-2-5014-001

Strep-Tactin(R)XT 4Flow(R) columns contain a 4% agarose coupled with the streptavidin variant Strep-Tactin(R)XT and are applicable for purification of Strep-tag(R)II or Twin-Strep-tag(R) fusion proteins via gravity flow. Due to the broad pH compatibility, excellent pressure stability, outstanding target purity (>...
Application: Gravity flow column to purify Strep-tag(R)II or Twin-Strep-tag(R) fusion proteins
482.00€ *
Review
NEW
Strep-Tactin(R)XT 4Flow(R) FPLC column
Strep-Tactin(R)XT 4Flow(R) FPLC column

Item number: IBA-2-5023-001

Strep-Tactin(R)XT 4Flow(R) cartridges contain a 4% agarose coupled with the streptavidin variant Strep-Tactin(R)XT and are applicable for purification of Strep-tag(R)II or Twin-Strep-tag(R) fusion proteins with HPLC/FPLC devices like Äkta(R) systems (Cytiva). Due to the broad pH compatibility, excellent pressure...
Application: HPLC/FPLC cartridge to purify Strep-tag(R)II or Twin-Strep-tag(R) fusion proteins
98.00€ *
Review
NEW
Strep-Tactin(R)XT 4Flow(R) FPLC column
Strep-Tactin(R)XT 4Flow(R) FPLC column

Item number: IBA-2-5024-001

Strep-Tactin(R)XT 4Flow(R) cartridges contain a 4% agarose coupled with the streptavidin variant Strep-Tactin(R)XT and are applicable for purification of Strep-tag(R)II or Twin-Strep-tag(R) fusion proteins with HPLC/FPLC devices like Äkta(R) systems (Cytiva). Due to the broad pH compatibility, excellent pressure...
Application: HPLC/FPLC cartridge to purify Strep-tag(R)II or Twin-Strep-tag(R) fusion proteins
256.00€ *
Review
NEW
Strep-Tactin(R)XT 4Flow(R) high capacity FPLC column, 1 ml
Strep-Tactin(R)XT 4Flow(R) high capacity FPLC column, 1 ml

Item number: IBA-2-5027-001

Strep-Tactin(R)XT 4Flow(R) cartridges contain a 4% agarose coupled with the streptavidin variant Strep-Tactin(R)XT and are applicable for purification of Strep-tag(R)II or Twin-Strep-tag(R) fusion proteins with HPLC/FPLC devices like Äkta(R) systems (Cytiva). Due to the broad pH compatibility, excellent pressure...
Application: HPLC/FPLC cartridge to purify Strep-tag(R)II or Twin-Strep-tag(R) fusion proteins
128.00€ *
Review
NEW
Strep-Tactin(R)XT 4Flow(R) high capacity FPLC column, 5ml
Strep-Tactin(R)XT 4Flow(R) high capacity FPLC column, 5ml

Item number: IBA-2-5028-001

Strep-Tactin(R)XT 4Flow(R) cartridges contain a 4% agarose coupled with the streptavidin variant Strep-Tactin(R)XT and are applicable for purification of Strep-tag(R)II or Twin-Strep-tag(R) fusion proteins with HPLC/FPLC devices like Äkta(R) systems (Cytiva). Due to the broad pH compatibility, excellent pressure...
Application: HPLC/FPLC cartridge to purify Strep-tag(R)II or Twin-Strep-tag(R) fusion proteins
373.00€ *
Review
2 from 14 pages